![]() ![]() If you need assistance choosing the right conventional fire alarm panel feel free to contact us on 01792 452 700. Siemens Industry Catalog - Building Technologies - Fire safety (EN) - Fire protection systems - Sinteso - Networkable fire control panels and terminals - FC20xx Networkable fire control panels - FC2020 Series - FC2020. The size of batteries will be limited to the physical size of the panels’ enclosure so it is always prudent to check the required batteries do indeed fit. Instances where detectors and call points are completely mixed you must use diode bases which maintains the line integrity.Īs with any fire alarm system battery backup calculations must be undertaken to verify what size batteries are needed to sustain suitable functionality in the event of mains power failure. To guarantee this you may decide to install all call points on dedicated zones or in the case of mixed zones ensure the call points are connected before any detectors. Some conventional panels boast 4 or more sounder circuits which may be preferable depending upon how many sounders you require and/or wiring configuration.īS5839 fire alarm standard outlines that should a detector be removed from its base all manual call points must still be operational. The capacity of each sounder circuit will be limited to its current rating. Whilst the simplicity of conventional panels means the biggest defining factor is the number of zones there are some other considerations to bear in mind including the following Evotech AS is a very versatile range of open protocol fire alarm control panels compatible with existing Evotech fire alarm panel technology. ![]() If you wish to install such a conventional system it is always wise to check the compatibility beforehand. Whilst not true in all cases it typically allows an installer to opt for their preferred panel, detectors, call points and sounders from a variety of sources. In reality many installations utilise a single sounder circuit for the majority of sounders and simply fit a single sounder next to the panel on the 2 nd circuit.Ĭonventional fire systems benefit from wide spread compatibility between various manufacturers panels and devices. Ideally all sounders should be evenly distributed across both sounder circuits and throughout the property to give the best coverage in the event of a fault such as a cable break. All conventional panels will have a minimum of 2 sounder circuits as the BS5839 fire standard dictates that in the event of a fault at least one sounder should remain operational. End of line monitoring is achieved by using either an end of line diode or capacitor, which are supplied with each panel and should be fitted into the last final device of every zone.Ĭonventional panels have separate sounder circuits that power any warning devices (sounders, flashers and/or combined). a radial circuit is required for every zone). Systems greater than 8 zones would benefit from the wiring advantages of 2 wire or addressable fire alarm panels.Īll detectors and call points for each zone are connected in a radial circuit that starts at the panel and ends at the last device (i.e. Certainly in the UK it is rare to see any fire system installation using more than an 8 zone conventional panel. We supply conventional panels that range from a single zone up to 24 zones and even 48 zone panels are available upon request. To comply with the British fire alarm standard BS5839 a property must be divided into zones, each zone can be considered as physical area for the purposes of locating a fire. Automatic External Defibrillators (AED) Cabinets. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |